Blood glucose monitors (BGMs) are essential tools for individuals managing diabetes. They provide crucial data, allowing users to track their blood sugar levels and make informed decisions about diet, medication, and activity. However, the accuracy of a BGM isn't a given; it hinges on calibration. Calibration is the process of setting a device to measure accurately, using a known standard. In the context of a BGM, this means aligning the device's readings with an expected value, typically set using a control solution. Proper BGM calibration is crucial for accurate readings, enabling effective diabetes management. Without proper calibration, the monitor might provide inaccurate results which can lead to errors in treatment decisions with potentially serious health consequences, such as either hypoglycemia (low blood sugar) or hyperglycemia (high blood sugar). These inaccurate readings can cause unnecessary stress and worry, making it more difficult to maintain health and well-being. It is not a “nice to have” feature; rather, it is a cornerstone of accurate and effective diabetes care.

The consequences of using a poorly calibrated BGM are significant. Inaccurate readings can result in misinterpretations of blood glucose patterns, leading to inappropriate medication dosages or poor nutritional choices. For instance, an under-reading monitor may lead an individual to think their blood sugar is lower than it actually is. Conversely, an over-reading BGM can suggest elevated glucose levels, when this may not be the case, and cause users to over-compensate with increased insulin. Both scenarios can disrupt blood sugar control, making it more difficult to manage the condition, and creating an unnecessary cycle of high glucose variability which has a detrimental effect on health.

To summarize, BGM calibration is a key part of using the device for both individuals and the healthcare providers that work with patients who use them. Accurate readings of glucose values must be consistently achieved to make informed treatment decisions. Therefore, regular calibration is paramount in order to reduce error and increase both treatment effectiveness and quality of life.


The Science Behind Calibration and How It Works

The underlying principle of BGM calibration revolves around the application of a reference solution, or more precisely a control solution, that contains a known concentration of glucose. This solution is introduced to the BGM similarly to how a blood sample is taken. The BGM's internal mechanism then processes the solution, and its reading is compared against the expected concentration from the control solution. This comparison is how the BGM determines whether to adjust or to keep the baseline standard of measurement that was preprogrammed when it was manufactured.

Here's how the process generally works:

  1. Using a Control Solution: This solution contains a known glucose concentration as indicated by the manufacturer (e.g., low, medium, or high). Control solutions are available from the BGM manufacturer and may need to be specific to your BGM type. The expiration date should also be observed, and new bottles may be required every few months.
  2. Initiating the Calibration: Following the instructions for your specific meter, place the control solution on a new test strip in order to initiate a testing cycle, as if taking a blood sample. Ensure that you are observing aseptic practices during the process to avoid any contaminates from entering the testing system and affecting your results.
  3. Reading Comparison: The BGM displays a reading after processing the control solution. This reading is then compared to the known value indicated by the manufacturer on the control solution bottle or within the user guide for your BGM system.
  4. Adjustment or Verification: Based on the reading, the BGM can either recalibrate automatically or you will have to assess the reading according to the tolerances given by the BGM manufacturer. This is either an internal function or a manual adjustment done by following the specific directions for your BGM model. The tolerance range will vary, but is frequently within +/-15% of the target value. If the meter reading is within this range then you know that the meter can be deemed accurate. If it does not pass this test, then troubleshooting will need to take place, such as acquiring new testing strips or replacing your meter.

Understanding the Components:

Component Function
Test Strip Holds the sample for glucose testing
Control Solution Standardized solution with a known glucose level
BGM Meter Processes the glucose and displays results
Calibration Key or Strip Adjusts the baseline measurement parameters for accuracy and reliability

Most modern BGMs use the electrochemical approach for sensing glucose. This involves the oxidation of glucose by a special enzyme (typically glucose oxidase or dehydrogenase), and as glucose is oxidized an electrical current is generated, which can be measured. Based on how much current is produced in the reaction, the meter will derive the measured glucose concentration. Variations in strip composition and production methods over time, will make it essential to regularly calibrate in order to increase accuracy. This is because, a new box of test strips may read differently, even if from the same manufacturer.

It’s important to note that environmental factors, such as humidity and temperature can affect results. In addition, improper handling of strips and expired strips can also affect readings. Always store your BGM and testing supplies as instructed in the manufacturers literature. By regularly completing the calibration process with a control solution, you can confirm if your glucose readings are accurate and ensure the reliable functioning of your BGM device.


Step-by-Step Guide to Calibrating Your Blood Glucose Monitor

While the specific calibration process may slightly vary depending on the BGM model, here's a general guide that you can adapt to your specific needs:

  1. Gather Your Supplies:

    • Your blood glucose monitor.
    • A new test strip from an unopened vial.
    • A bottle of control solution that is appropriate for your meter. Note whether it is a high, medium, or low control.
    • Instructions for your specific BGM.
    • Your lancing device for testing with blood if needed.
  2. Wash and Prepare:

    • Before starting the calibration test, make sure your hands are clean and dry, to avoid cross-contamination of the test.
    • It may be necessary to ensure that your hands are warm before calibrating with blood if that is your method.
  3. Insert a New Test Strip:

    • Insert a new test strip into your BGM meter, making sure it’s positioned correctly. The meter should turn on automatically or follow the manufacturers instructions to initialize testing.
  4. Apply the Control Solution:

    • Before applying control solution to the strip, be sure that the bottle is shaken to ensure the glucose is evenly distributed in the fluid.
      • If you are using a control solution, apply a small drop onto the end of the testing strip, following the instructions of your manufacturer. Do not squeeze the bottle as this may create errors in the solution volume being applied.
  5. Initiate the Test:

    • Your meter should begin testing after the control solution has been applied.
  6. Check Your Reading:

    • Once the test is completed, the screen on your BGM will display the resulting reading from your calibration procedure.
  7. Compare to Control Range:

    • Find the expected range for your specific control solution as indicated by your control solution manufacturer. You may need to refer to your user manual for this, or the label of your control solution bottle. This range is crucial for assessing the accuracy of your meter. Usually it’s within +/- 15%.
  8. Interpret the Results:

    • If the reading falls within the specified range: This indicates that your meter is calibrated correctly. However, regular testing of the meter should still be done before every session of blood glucose testing, especially if the bottle or batch of testing strips are new.
    • If the reading falls outside the specified range: Your BGM is not currently calibrated correctly, and you should repeat the calibration process. If the issue persists, refer to your meter's instruction manual for troubleshooting guidance, or contact the manufacturer directly to inquire about repair and replacement options. It may also be an indication that your current box of testing strips are faulty, or that your control solution has expired.
    • Blood-based Calibration (if required): Some older models require a blood sample to set baseline calibration. This involves a blood test, followed by the same process as with control solution, and it should always be done in consultation with your doctor. It may also be important to note the potential differences between the readings of whole blood versus plasma in blood-based meters. There can be up to 10-15% difference between whole blood and plasma tests in glucose readings.
  9. Document: Ensure to record your calibration information, so that you know which date you tested your meter. If there are multiple meter users, be sure to note who is testing and that the readings for blood glucose values are within normal parameters before use on any new person,

Table: Calibration Troubleshooting Steps

Issue Action
Reading outside range Repeat calibration test. Check expiry date of solution.
Meter showing error code Consult manual or call manufacturer
Inconsistent results Check expiration of test strips, proper storage of the meter and strips. Repeat with new strips

Best Practices for Maintaining Accuracy and Troubleshooting Issues

Beyond regular calibration, several practices can help maintain the accuracy of your BGM:

  1. Test Strip Management:

    • Storage: Store test strips in their original container, in a cool, dry place, and avoid temperature fluctuations, and direct sunlight. Heat and moisture can damage test strips leading to inaccurate results.
    • Expiry Dates: Check expiry dates of the testing strips before use. Using expired test strips can result in erroneous readings.
      • Handling: Avoid touching the test area of the strip with your fingers to prevent contamination. Contamination from the skin, or moisture will interfere with chemical reactions that will lead to inaccuracies. Do not squeeze, drop, bend, or damage the testing strips, and always store in the original container.
  2. Meter Maintenance:

    • Cleaning: Gently wipe the meter with a soft, dry cloth, as needed and indicated by the manufacturer. Do not clean it with any liquids that are not indicated by the manufacturer, as this may corrode it. Keep all the ports free of debris or dust.
      • Temperature: Extreme temperatures can impact meter performance. Refer to your user manual for optimal operating temperature.
      • Battery Status: Keep the battery in your BGM fully charged. If the battery is low this may interfere with readings.
  3. Regular Controls Testing:

    • Calibrate regularly: At least once a week or each time you open a new vial of test strips. If you are having issues with consistent readings, a calibration test should always be performed to rule out accuracy issues.
  4. Blood-based testing preparation:

    • Hygiene: Wash and dry your hands thoroughly before testing your blood with a BGM.
    • Lancing: Use a proper technique for obtaining a blood sample, following the directions of your meter. Use new lances each testing session, and adjust the depth of the lance to avoid unnecessary discomfort.
    • Sample volume: Ensure that there is an appropriate sized sample for accurate reading. Many meters will flash warnings if the sample is too small, too big, or if the sample is contaminated.

When to Seek Professional Help:

  • If your BGM consistently provides readings that are inconsistent, it may be time to seek advice from a professional medical team for guidance on troubleshooting.
  • If your BGM fails multiple control tests in a row, then it may require replacement or repair. Contact the BGM manufacture or your medical doctor for advice on replacement options.
  • If your readings are consistently and noticeably outside of your target range, it’s essential to contact your doctor for a medical assessment and treatment adjustments.
  • If you have difficulties using the meter, a doctor or diabetes education specialist can help provide personalized and tailored advice.
  • It’s also important to consult with a healthcare professional when switching BGM brands. The calibration methods and ranges may vary among different brands and testing technologies. This can provide an added level of safety when using a new type of meter for your needs.

In conclusion, diligent calibration and adherence to the above best practices will ensure the reliability and accuracy of your blood glucose monitoring system. Regular checks and proper techniques will help to manage your blood glucose level better, with increased confidence, ultimately leading to better health outcomes.